Reliance Automation's patented control system continuously monitors DAF influent and effluent, runs automated jar tests when conditions change, and implements the lowest-cost chemical combination that hits target clarity — 24/7/365.
A manual jar test is a snapshot of a single moment. Wastewater doesn't hold still — a fryer dump, a marination discharge, or a sanitation cycle changes the zeta potential of the stream, and the dosage that worked an hour ago stops working.
Reliance Automation's system watches DAF influent and effluent continuously. When it detects an upset, it runs the jar test itself — testing pre-programmed coagulant and polymer combinations — and implements new pump settings the moment it finds the combination that hits target clarity.
If more than one combination gets the same result, the system selects the lowest-cost option automatically.
A closed loop that runs whether or not anyone is watching the DAF.
Turbidity or TSS sensors read DAF influent and effluent continuously, in real time.
When effluent clarity moves outside the set point, the system flags an upset and triggers a test.
The PLC runs an automated jar test — incrementally trying pre-programmed coagulant and polymer combinations.
Once optimal clarity is found, new pump settings go live — the lowest-cost combination wins on a tie.
Ideal for plants where equalization is minimized and conditions shift shift-to-shift.
Cooking oil discharges, marination, blood, and sanitation cycles all shift the zeta potential of the wastewater stream — often within the same shift.
Process water and pretreatment systems where flow and composition change with production — and a missed dosage window means a compliance event.
Plants with limited operator coverage and minimal equalization, where discharge compliance depends on catching changes as they happen.
A poultry further-processing plant ran a three-part polymer program (coagulant, anionic, and cationic polymer) through a DAF unit before discharging to the city. Cooking oil, marination, blood, and sanitation discharges repeatedly shifted the wastewater's zeta potential faster than operators could react. Jar tests — run in mL/L and converted by hand to mL/min pump settings — rarely kept pace. Surcharges exceeded $300,000 in 2008 and were on pace to double in 2009, driven mainly by TSS and BOD violations. Six operators were needed to monitor the DAF around the clock.
Reliance Automation installed turbidity sensors before and after the DAF and programmed a PLC with a range of polymer combinations. When turbidity rose above set points, the system automatically ran through combinations until it found the one that restored optimal clarity — and defaulted to the lowest-cost option whenever more than one worked equally well.
Beyond the Alabama result, these are the categories of impact the system is built to produce on any DAF or clarifier line.
Chemical use reduction, reduced manpower needs, and reduced chemical storage on site.
Fewer notices of violation, stronger regulatory compliance, and continuous wastewater data for reporting.
Automated control that adapts to variable flow rates and process changes without operator recalculation.
Water reduction and reuse, sludge reduction, and system-wide chemical optimization.
Units installed in the field are still running after 9+ years of continuous service. Full technical documentation is available on request.
Reliance Automation, LLC builds and installs the Automated Polymer Feed System — a patented control platform that replaces manual jar testing with continuous, automated wastewater treatment optimization.
We work directly with plant operators and engineers, from initial assessment through installation and ongoing support, fitting the system to each facility's existing DAF, clarifier, and control infrastructure.
Tell us about your DAF or clarifier setup and current dosing process — we'll follow up to scope what automation could look like on your line.